貨運空氣淋浴間是一種重型污染控制裝置,專為在託盤、紙箱、桶、設備和原材料進入潔淨室或受控環境之前進行清潔而設計。 它引導高速HEPA過濾的空氣通過可調節的噴嘴去除灰塵,
The Cargo Air Shower Room is a heavy-duty contamination control unit designed specifically for cleaning pallets, cartons, drums, equipment, and raw materials before they enter a cleanroom or controlled environment. It directs high-velocity HEPA-filtered air through adjustable nozzles to remove dust, particles, and fibers from external surfaces of incoming goods.
This unit is essential for facilities where material transfer poses a contamination risk, ensuring that only clean items pass into the production area.
Large Internal Clearance
Oversized dimensions accommodate standard pallets (800×1200 mm), drums, trolleys, and even small forklifts.
High-Efficiency Filtration
Equipped with HEPA or ULPA filters (≥99.99% efficiency at 0.3 µm or 0.1 µm) to deliver particle-free air jets.
Interlocked Doors
Heavy-duty magnetic or electronic interlocks prevent both entry and exit doors from opening simultaneously, maintaining cleanroom pressure and preventing cross-contamination.
Multi-Directional Air Nozzles
Strategically placed stainless steel or ABS nozzles on side walls, ceiling, and optionally the floor to ensure complete surface coverage (360° cleaning).
PLC Control System with HMI
Industrial-grade controller with adjustable cycle time (15–300 seconds), emergency stop, automatic cycle start, cycle counter, and audible completion alarm.
Rugged Industrial Construction
Manufactured from 304 stainless steel (or 316L for corrosive environments) with seamless welding and rounded corners for easy cleaning.
Energy-Saving Operation
Low-noise blower with standby mode and timer-controlled shutdown reduces power consumption between cycles.
使用風速計定期檢查風速(必須保持20m/s)。根據壓差計讀數或定期維護計畫更換預篩檢程式和HEPA篩檢程式。每月用無絨布清潔內壁
嚴格遵守最大入住人數(通常為1-2人)。擁擠會擾亂室內氣流,導致淨化不徹底。允許各組之間有間隔進行自我淨化。
換上專用的無絨布潔淨室衣服,確保頭髮完全被帽子覆蓋,摘下所有珠寶,避免掉掉顆粒的化妝品和香水。街頭衣服是重要的污染源。
靜止會產生淨化“死角”,氣流無法到達背部、腋下和膝蓋等部位。手臂運動的主動旋轉(至少一整圈)可確保完全暴露在表面。
打開兩扇門會繞過氣閘功能,允許未經過濾的非清潔空氣直接流入清潔區,完全破壞壓差並影響清潔度分類
進入,完全關閉外門,站在中心,抬起手臂緩慢旋轉360度以進行徹底覆蓋,等待預設時間(15-30秒),然後打開內門並進入潔淨區
安裝在更衣室和潔淨區之間,或ISO 8/ISO 7分類區和不潔淨區之間。 人員在換上潔淨室服裝後進入受控環境之前通過。